Accessories · Power

Power supplies and adapters for Hikrobot cameras and readers

Power

Power supplies and adapters for Hikrobot cameras, code readers and controllers: 12 V and 24 V desktop adapters, enclosed industrial chassis-mount units, and 48 V sources for ID7000. The correct unit depends on the specific model; include the model in your request.

Price on requestAn engineer will confirm pricing and lead time in the first reply.
Lead time
from 5 days
Warranty
36 months
Find the right model
Hikrobot Power supplies and adapters for Hikrobot cameras and readers

Part numbers and versions

Cable installation scenariostatic1
Cable colorblack1
Derating start temperature50 °C1
Overcurrent relative threshold>120 %1
Overvoltage protection modeshutdown; restart to restore1
Part numberPNIntegral cable lengthConnector AConnector B
KPL-060F-VI
All specifications
Power supply
90…264 V @ AC
Connector set
IEC C14 → open leads 2-pin
Output current
0…5 A
Output voltage
12 V @ DC
Power supply output power
≤60 W (max.)
Cable construction
2 cores 18 AWG
Working temperature
0…40 °C
Certification
UL, cUL, CB, CCC, BSMI, GS, S-MARK, RCM, KC, PSE, VCCI, EAC, NOM, BIS, CE, IC, RoHS
AC plug
—
Cold-start inrush current
100 A @ AC, cold start, supply voltage 240 V; 60 A @ AC, cold start, supply voltage 100 V
Input current
1.7 A
Lifetime
17520 h @ ambient temperature 25 °C, load 100 %
MTBF
100000 h @ ambient temperature 25 °C, load 100 %
Overcurrent protection
5.8…9 A
Overvoltage protection
≤19 V (max.)
Derating rate
—
Overcurrent mode
—
310100900
0.8 m
IEC C14
open leads 2-pin
KPL-060M-VI
All specifications
Power supply
90…264 V @ AC
Connector set
IEC C14 → open leads 2-pin
Output current
0…2.5 A
Output voltage
24 V @ DC
Power supply output power
≤60 W (max.)
Cable construction
1 core 18 AWG + shield (S)
Working temperature
-10…45 °C
Certification
UL, cUL, CB, CCC, BSMI, GS, S-MARK, RCM, KC, PSE, VCCI, EAC, CE, IC, RoHS
AC plug
—
Cold-start inrush current
100 A @ AC, cold start, supply voltage 240 V; 60 A @ AC, cold start, supply voltage 100 V
Input current
1.7 A
Lifetime
8760 h @ ambient temperature 40 °C, load 100 %
MTBF
100000 h @ ambient temperature 25 °C, load 100 %
Overcurrent protection
3…4 A
Overvoltage protection
≤37.5 V (max.)
Derating rate
—
Overcurrent mode
—
310100901
1.2 m
IEC C14
open leads 2-pin
ADS-12FG-12N 12012EPCN
All specifications
Power supply
90…264 V @ AC
Connector set
AC plug two-prong AC plug (CCC standard) 2-pin male → open leads 2-pin
Output current
0…1 A
Output voltage
12 V @ DC
Power supply output power
≤12 W (max.)
Cable construction
2 cores 24 AWG (F) (11×0.16 mm)
Working temperature
0…40 °C
Certification
RoHS, CCC
AC plug
China plug (CCC)
Cold-start inrush current
—
Input current
0.3 A
Lifetime
17520 h @ ambient temperature 25 °C, load 100 %
MTBF
50000 h
Overcurrent protection
1.1…2 A
Overvoltage protection
≤15 V (max.)
Derating rate
—
Overcurrent mode
—
310100898
1.5 m
AC plug two-prong AC plug (CCC standard) 2-pin male
open leads 2-pin
ADS-26FSG-12 12024EPCN
All specifications
Power supply
—
Connector set
—
Output current
—
Output voltage
—
Power supply output power
—
Cable construction
—
Working temperature
—
Certification
—
AC plug
—
Cold-start inrush current
—
Input current
—
Lifetime
—
MTBF
—
Overcurrent protection
—
Overvoltage protection
—
Derating rate
—
Overcurrent mode
—
310100899
—
—
—
ADS-26FSG-12 12018EPK (DC Connector)
All specifications
Power supply
100…240 V @ AC
Connector set
—
Output current
0…1.5 A
Output voltage
12 V @ DC
Power supply output power
≤18 W (max.)
Cable construction
—
Working temperature
—
Certification
—
AC plug
Korea plug (KC)
Cold-start inrush current
—
Input current
—
Lifetime
—
MTBF
—
Overcurrent protection
—
Overvoltage protection
—
Derating rate
—
Overcurrent mode
—
101701111
—
—
DC barrel, inner ⌀ 2.1 mm
ADS-26FSG-12 12024EPB (DC Connector)
All specifications
Power supply
100…240 V @ AC
Connector set
—
Output current
0…2 A
Output voltage
12 V @ DC
Power supply output power
≤24 W (max.)
Cable construction
—
Working temperature
—
Certification
—
AC plug
UK
Cold-start inrush current
—
Input current
—
Lifetime
—
MTBF
—
Overcurrent protection
—
Overvoltage protection
—
Derating rate
—
Overcurrent mode
—
101700710
—
—
DC barrel, inner ⌀ 2.1 mm
ADS-26FSG-12 12024EPCN (DC Connector)
All specifications
Power supply
90…264 V @ AC
Connector set
AC plug two-prong AC plug (CCC standard) 2-pin male → DC barrel, 5.5/2.1 mm, length 10 mm
Output current
0…2 A
Output voltage
12 V @ DC
Power supply output power
≤24 W (max.)
Cable construction
cores 22 AWG
Working temperature
-10…40 °C
Certification
RoHS, CCC
AC plug
China plug (CCC)
Cold-start inrush current
—
Input current
0.3 A
Lifetime
—
MTBF
100000 h
Overcurrent protection
3.2…6.5 A
Overvoltage protection
≤18 V (max.)
Derating rate
—
Overcurrent mode
—
310101855
1.2 m
AC plug 2-pin
DC barrel, 5.5/2.1 mm, length 10 mm
ADS-26FSG-12 12024EPCU/EPC (DC Connector)
All specifications
Power supply
100…240 V @ AC
Connector set
—
Output current
0…2 A
Output voltage
12 V @ DC
Power supply output power
≤24 W (max.)
Cable construction
—
Working temperature
—
Certification
—
AC plug
US
Cold-start inrush current
—
Input current
—
Lifetime
—
MTBF
—
Overcurrent protection
—
Overvoltage protection
—
Derating rate
—
Overcurrent mode
—
101700666
—
—
DC barrel, inner ⌀ 2.1 mm
ADS-26FSG-12 12024EPG (DC Connector)
All specifications
Power supply
100…240 V @ AC
Connector set
—
Output current
0…2 A
Output voltage
12 V @ DC
Power supply output power
≤24 W (max.)
Cable construction
—
Working temperature
—
Certification
—
AC plug
EU
Cold-start inrush current
—
Input current
—
Lifetime
—
MTBF
—
Overcurrent protection
—
Overvoltage protection
—
Derating rate
—
Overcurrent mode
—
101700708
—
—
DC barrel, inner ⌀ 2.1 mm
ERPF-400-48
All specifications
Power supply
90…264 V @ AC
Connector set
—
Output current
0…8.3 A
Output voltage
48 V @ DC
Power supply output power
≤398.4 W (max.)
Cable construction
—
Working temperature
—
Certification
—
AC plug
—
Cold-start inrush current
—
Input current
—
Lifetime
—
MTBF
—
Overcurrent protection
—
Overvoltage protection
—
Derating rate
—
Overcurrent mode
—
101701338
—
—
terminal block
GKF-320-48II
All specifications
Power supply
100…240 V @ AC
Connector set
—
Output current
0…6.7 A
Output voltage
48 V @ DC
Power supply output power
≤320 W (max.)
Cable construction
—
Working temperature
—
Certification
—
AC plug
—
Cold-start inrush current
—
Input current
—
Lifetime
—
MTBF
—
Overcurrent protection
—
Overvoltage protection
—
Derating rate
—
Overcurrent mode
—
101701390
—
—
terminal block
KPE150M-VI
All specifications
Power supply
90…264 V @ AC
Connector set
open leads 2-pin; IEC C14
Output current
0…6.25 A
Output voltage
24 V @ DC
Power supply output power
≤150 W (max.)
Cable construction
2 cores 16 AWG
Working temperature
-10…40 °C
Certification
CE, CCC, KC, TUV, GS, UL, RoHS
AC plug
—
Cold-start inrush current
120 A @ AC, cold start, supply voltage 240 V; 100 A @ AC, cold start, supply voltage 100 V
Input current
2.1 A
Lifetime
8760 h @ ambient temperature 40 °C, load 100 %
MTBF
100000 h @ ambient temperature 25 °C, load 100 %
Overcurrent protection
7…11 A
Overvoltage protection
≤30 V (max.)
Derating rate
—
Overcurrent mode
—
310100902
1.2 m
IEC C14
open leads 2-pin
KPL-060M-II
All specifications
Power supply
—
Connector set
—
Output current
0…2.5 A
Output voltage
24 V @ DC
Power supply output power
≤60 W (max.)
Cable construction
—
Working temperature
—
Certification
—
AC plug
—
Cold-start inrush current
—
Input current
—
Lifetime
—
MTBF
—
Overcurrent protection
—
Overvoltage protection
—
Derating rate
—
Overcurrent mode
—
101701011
—
—
DC barrel, inner ⌀ 2.1 mm
LRS-150F-24
All specifications
Power supply
85…264 V @ AC; 125…375 V @ DC
Connector set
—
Output current
0…6.25 A
Output voltage
24 V
Power supply output power
150 W (max.)
Cable construction
—
Working temperature
-30…70 °C
Certification
CE, UL, CCC, SIQ
AC plug
—
Cold-start inrush current
—
Input current
1.7 A @ AC, supply voltage 115 V; 1 A @ AC, supply voltage 230 V
Lifetime
—
MTBF
700000 h
Overcurrent protection
—
Overvoltage protection
28.8…33.6 V
Derating rate
2 %/°C @ ambient temperature above 50 °C
Overcurrent mode
hiccup
310100904
—
terminal block @ AC/DC
terminal block
LRS-50-12
All specifications
Power supply
90…264 V @ AC
Connector set
—
Output current
0…4.17 A
Output voltage
12 V
Power supply output power
50 W (max.)
Cable construction
—
Working temperature
-10…70 °C
Certification
CE, UL, CCC, NRCan, EAC
AC plug
—
Cold-start inrush current
—
Input current
1.1 A @ AC, supply voltage 115 V; 0.7 A @ AC, supply voltage 230 V
Lifetime
—
MTBF
700000 h
Overcurrent protection
—
Overvoltage protection
13.8…16.2 V
Derating rate
2.5 %/°C @ ambient temperature above 50 °C
Overcurrent mode
hiccup, automatic recovery
310100903
—
terminal block
terminal block
LRS-50-24
All specifications
Power supply
85…264 V @ AC
Connector set
—
Output current
0…2.09 A
Output voltage
24 V
Power supply output power
50 W (max.)
Cable construction
—
Working temperature
-10…70 °C
Certification
CE, UL, CCC
AC plug
—
Cold-start inrush current
—
Input current
1.1 A @ AC, supply voltage 115 V; 0.65 A @ AC, supply voltage 230 V
Lifetime
—
MTBF
200000 h
Overcurrent protection
—
Overvoltage protection
28.8…33.6 V
Derating rate
2.5 %/°C @ ambient temperature above 50 °C
Overcurrent mode
hiccup, automatic recovery
310100905
—
terminal block
terminal block
LRS-75-48
All specifications
Power supply
85…264 V @ AC; 120…373 V @ DC
Connector set
—
Output current
0…1.6 A
Output voltage
48 V
Power supply output power
76.8 W (max.)
Cable construction
—
Working temperature
-30…70 °C
Certification
CE, UL, CCC, EMC, EAC, TUV, UK
AC plug
—
Cold-start inrush current
—
Input current
1.4 A @ AC, supply voltage 115 V; 0.85 A @ AC, supply voltage 230 V
Lifetime
—
MTBF
3334300 h
Overcurrent protection
—
Overvoltage protection
55.2…64.8 V
Derating rate
2 %/°C @ ambient temperature above 50 °C
Overcurrent mode
hiccup
310100906
—
terminal block
terminal block

1 not stated for all variants

Compatible cameras and code readers

Series per manufacturer data:

ID2000EMID2000MID3000PMID3000XMID5000ID5000XID7000ID7000-LID800IDHMV-IDH3000-RJ45MV-IDH3000BMV-IDH7000BMV-IDH7000P-RJ45

and 13 more series

FAQ

Which output-voltage groups are covered by these supplies?

The listed units provide 12 V, 24 V, or 48 V outputs. The category description specifically associates 48 V sources with ID7000, while the full device list includes ID, SC, PD, and VC groups.

How should current and wattage be checked after voltage?

Match both ratings to the connected load after fixing the required 12 V, 24 V, or 48 V output. Each voltage group contains multiple current and wattage combinations, and they are assigned to specific units.

What input-plug choices appear on DC-connector adapters?

DC-connector variants are listed with KC, UK, two-prong AC, and EU plug descriptions. Other assemblies terminate in open leads, so the regional AC connection and the equipment-side DC ending require separate checks.

How do desktop adapters differ from enclosed chassis units?

Desktop adapters combine an AC-side plug or lead with a defined equipment-side termination. Enclosed industrial units are chassis-mounted and selected around their 12 V, 24 V, or 48 V output rating, current, and power.

Which cable lengths are stated for cable-equipped power units?

The listed lead lengths are 0.8 m, 1.2 m, and 1.5 m. Length belongs to a specific adapter and termination, so it should be checked together with the AC plug, open-lead or DC-connector ending, and electrical rating.

Typical applications