Hybrid cables for Hikrobot fixed-mount ID code readers. Depending on the reader interface, the reader end uses an M12 A-code 17-pin connector or a DB15 connector; the other end provides RJ45, DB9, USB and/or terminal connections plus open power/IO leads. Breakout configurations vary; cross-check the table against your wiring diagram.

Price on requestAn engineer will confirm pricing and lead time in the first reply.
Lead time
from 5 days
Warranty
36 months
Find the right model
Hikrobot Data cables for ID code readers (MV-IDA-PE)

Part numbers and versions

M12 17-pin reader connector — Standard (ST)

Part numberPNConnectorsLength
MV-IDA-PE-M12A17pF-opensU2DB9-ST-2m310101295M12 A-coded 17-pin male → TB3B8P + USB 2.0 + DB9 female2 m
MV-IDAPE-M12A17F-U2DC-ST-2m310102959M12 A-coded 17-pin male → USB 2.0 + DC2 m
MV-IDA-PE-M12A17pF-openRJ45DB9-ST-3m310101292M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female3 m
MV-IDA-PE-M12A17pF-openRJ45FDB9-ST-3m310101871M12 A-coded 17-pin male → TB3B8P + RJ45 female + DB9 female3 m
MV-IDA-PE-M12A17pFUP-openRJ45DB9-ST-3m310101869M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female (upward-facing connector)3 m
MV-IDA-PE-M12A17pF-opensRJ45DB9-ST-5m310101293M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female5 m
MV-IDA-PE-M12A17pFUP-openRJ45DB9-ST-5m310101877M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female (upward-facing connector)5 m
MV-IDA-PE-M12A17pF-openRJ45DB9-ST-7m310101873M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female7 m
MV-IDA-PE-M12A17pF-opensRJ45DB9-ST-10m310101294M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female10 m
MV-IDA-PE-M12A17pFUP-openRJ45DB9-ST-10m310101878M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female (upward-facing connector)10 m
MV-IDA-PE-M12A17pF-opensRJ45DB9-ST-15m310101310M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female15 m

M12 17-pin reader connector — High-flex (HF)

Part numberPNConnectorsLength
MV-IDA-PE-M12A17pF-opensU2DB9-HF-2m310101297M12 A-coded 17-pin male → TB3B8P + USB 2.0 + DB9 female2 m
MV-IDA-PE-M12A17pF-openRJ45FDB9-HF-3m310101872M12 A-coded 17-pin male → TB3B8P + RJ45 female + DB9 female (upward-facing connector)3 m
MV-IDA-PE-M12A17pF-opensRJ45DB9-HF-3m310101296M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female3 m
MV-IDA-PE-M12A17pFUP-openRJ45DB9-HF-3m310101870M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female (upward-facing connector)3 m
MV-IDAPE-M12A17F-openRJ45DB9M-HF-5m310102637M12 A-coded 17-pin male → TB3B8P + RJ45 male + DB9 female5 m
MV-IDA-PE-M12A17pF-openRJ45DB9-HF-7m310101874M12 A-coded 17-pin male → 8-pin terminal + RJ45 male + DB9 female7 m
MV-IDA-PE-M12A17pF-openRJ45DB9-HF-10m310101875M12 A-coded 17-pin male → 8-pin terminal + RJ45 male + DB9 female10 m
MV-IDA-PE-M12A17pF-opensRJ45DB9-HF-15m310101307M12 A-coded 17-pin male → 8-pin terminal + RJ45 male + DB9 female15 m

M12 17-pin reader connector — Super-flex (SF)

Part numberPNConnectorsLength
MV-IDA-PE-M12A17pF-openRJ45DB9-SF-5m310101876M12 A-coded 17-pin male → 8-pin terminal + RJ45 male + DB9 female5 m

DB15 reader connector (early series) — Standard (ST)

Part numberPNConnectorsLength
MV-IDA-PE-HDB15-USB-ST-2m310102102DB15 male → USB 2.0 Type-A male2 m
MV-IDAPE-DB15M-USB--ST-2m310102616DB15 male → USB2 m
MV-IDAPE-DB15M-USBDB9FOPEN--ST-2m310102617DB15 male → USB + DB9 female + open leads2 m
MV-IDA-PE-HDB15-USBDB9Open-ST-2.5m310102104DB15 male → TB3B6P + DB9 (DC jack) + USB 2.0 Type-A male2.5 m
MV-IDA-PE-HDB15-USBRJ45DB9Open-ST-2.5m310102103DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 male + USB Type-A male2.5 m
MV-IDAPE-DB15M-DB9FRJ45OPEN-ST-3m310102618DB15 male → DB9 female + RJ45 + open leads3 m
MV-IDA-PE-HDB15-RJ45DB9Open-ST-3.5m310102105DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 male3.5 m
MV-IDA-PE-HDB15-RJ45DB9Open-ST-3.5m101525618DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 male3.5 m
MV-IDA-PE-HDB15-RJ45FDB9Open-ST-3.5m310102107DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 female3.5 m
MV-IDA-PE-HDB15-RJ45DB9Open-ST-5m310102108DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 male5 m
MV-IDAPE-DB15M-DB9FRJ45OPEN-ST-5m310102619DB15 male → DB9 female + RJ45 + open leads5 m
MV-IDAPE-DB15M-DB9FRJ45OPEN-ST-7m310102620DB15 male → DB9 female + RJ45 + open leads7 m
MV-IDAPE-DB15M-DB9FRJ45OPEN-ST-10m310102621DB15 male → DB9 female + RJ45 + open leads10 m
MV-IDA-PE-DB15-RJ45M/DB9/OPENS-ST-15101520791DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 male15 m
MV-IDA-PE-HDB15-RJ45DB9Open-ST-15m310102106DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 male15 m

DB15 reader connector (early series) — High-flex (HF)

Part numberPNConnectorsLength
MV-IDA-PE-HDB15-RJ45DB9Open-HF-5m310102109DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 male5 m
MV-IDA-PE-HDB15M-RJ45M/DB9F/TB3B6P-HF-5m101522574DB15 male → TB3B6P + DB9 female (DC jack) + RJ45 male5 m
MV-IDAPE-DB15M-DB9FRJ45OPEN-HF-5m310102622DB15 male → DB9 female + RJ45 + open leads5 m
MV-IDAPE-DB15M-DB9FRJ45OPEN-HF-7m310102623DB15 male → DB9 female + RJ45 + open leads7 m
MV-IDAPE-DB15M-DB9FRJ45OPEN-HF-10m310102624DB15 male → DB9 female + RJ45 + open leads10 m

Other breakouts — Standard (ST)

Part numberPNConnectorsLength
MV-IDA-PE-U2-U2-ST-2m101522133USB Type-A male → USB Type-B male2 m
MV-IDA-PE-Open9p-Open-ST-7m31010211110-pin terminal → open leads7 m

Compatible cameras and code readers

and 16 more — Code readers →

Equipment categories this accessory is matched to:

Series per manufacturer data:

ID2000M-RJ45ID2000M-USBID2000XM-RJ45ID2000XM-USBID2013EMID2013EM-RJ45ID2013EM-USBID2013EMI-RJ45ID2013EMI-USBID3000PMIDH2000RFSC2000ESC2000XSC3000

and 1 more series

FAQ

When is an M12 cable chosen instead of a DB15 assembly?

Use the connector fitted to the fixed reader. The two main branches are M12 A-coded 17-pin and DB15 male, with DB15 identified for early series. Their breakout families differ, so the device-end connector is the first filter.

How do Standard, High-flex and Super-flex groups differ?

The M12 branch contains Standard, High-flex and Super-flex classes. DB15 cables are listed in Standard and High-flex classes. Choose the flex class for the cable route, then compare only the connector and length options present in that class.

Which host-side breakouts occur on the M12 cables?

M12 assemblies combine TB3B8P or an 8-pin terminal with USB 2.0, RJ45 male or female, and DB9 female in different layouts. One 2 m version ends in USB 2.0 plus DC, and upward-facing variants are also listed.

What breakout choices are available for early-series DB15 readers?

The DB15 group includes USB-only cables and hybrid assemblies with DB9 female, RJ45, TB3B6P or open leads. RJ45 male and female forms appear in the Standard group, and High-flex hybrid entries are available at several lengths.

Why should cable length be checked after the connector layout?

Lengths extend from 2 m to 15 m, but not every length appears with every reader connector, breakout or flex class. First fix M12 or DB15 and the terminal, USB, RJ45, DB9 and open-lead requirements, then select an offered length.

Typical applications