3D laser profile sensor · DP3000 series Laser Profiler
Hikrobot MV-DP3120
- Lead time
- from 5 days
- Warranty
- 36 months

Fast profiling for deeper formed surfaces
An 80 to 86 mm Z envelope gives MV-DP3120 the depth needed for pronounced formed surfaces. The 01D version covers 80 mm at 117 mm; 01P and 03P cover 86 mm at 126 mm. All executions use 3200 points and run from 3.4 to 46.7 kHz in high-frame-rate mode, with stated repeatability of 1.48 µm for 01D and 1.68 µm for 01P and 03P.
The expanding X fields cover 57 to 91.4 mm for 01D and 65 to 105 mm for 01P and 03P, supporting height, contour and edge checks across a broad moving target. Gigabit Ethernet transfers the measurements, while 12-pin M12 power/I/O arrangements support differential timing and, on 01P, isolated input channels. The IP67 housing operates from 0 to 45 °C.
MV-DP3120 increases the rate over MV-DP2120, whose 80 mm executions run up to 23.9 kHz. MV-DP3300 keeps the 46.7 kHz ceiling but extends the Z range to 210 mm and reference field to 183 mm, with 2.20 µm repeatability. Choose MV-DP3120 for 80 to 86 mm depth and finer repeatability; choose MV-DP3300 for a much larger envelope.
Overview
A DP3000 series laser profiler — the mid class: the same 3200 points per profile at twice the scan rate, up to 46.7 kHz.
Working distance 126 mm, measurement range 86 mm.
Used where a profile is needed rather than a picture: weld bead control, adhesive bead height, gap and flush, warpage, parcel volume. Data goes to VM3D or 3DMVS, and to third-party software over a standard protocol.
Available versions
One device, different revisions. We ship the current one by default; if a specific revision is already installed on your line, name it in the request and we will match it.
| Part number | PN | |
|---|---|---|
| MV-DP3120-01D | 306400543 | |
| MV-DP3120-01P | 306400449 | |
| MV-DP3120-03P | 306400515 |
Specifications
| Data interface | GigE (Fast Ethernet compatible) |
| 3D scan rate | 3400…46700 Hz @ high frame rate mode |
| Points per profile | 3200 |
| Trigger mode | software, hardware, encoder |
| Laser safety class | 3R |
| Third party software protocol | 3D1 |
| Client software | 3DMVS, VM3D |
| Operating systems | Windows 7 (32/64-bit), Windows 10 (32/64-bit), Windows 11 (64-bit) |
| Digital I/O connector | M12 12-pin |
| Ingress protection | IP67 |
| Storage temperature | -30…80 °C |
| Humidity | 20…85 % @ non-condensing |
| Power supply connector | M12 12-pin |
| Recommended system CPU | Intel Core i51 |
| Required system CPU | Core i5 per manufacturer requirements1 |
| Part number | Depth measurement range | Reference distance | Reference field of view | Z resolution | Z repeatability |
|---|---|---|---|---|---|
MV-DP3120-01PAll specifications
| 86 mm | 126 mm | 85 mm | 4.38…8.33 µm | 1.68 µm (average) |
MV-DP3120-03PAll specifications
| 86 mm | 126 mm | 85 mm | 4.38…8.33 µm | 1.68 µm (average) |
MV-DP3120-01DAll specifications
| 80 mm | 117 mm | 74.2 mm | 3.9…7.56 µm | 1.48 µm |
1 not stated for all variants
Documents
Selection and applications
Deep contour measurement through an 80 or 86 mm Z range. Broad 3200-point profile capture across formed surfaces. High-rate line scanning up to 19 or 46.7 kHz.
Minimum kit: MV-DP3120, a Gigabit Ethernet cable, a 12-pin M12 power and I/O cable matched to the execution, a 24 VDC supply, and a 3DMVS, VM3D or third-party software host form the minimum acquisition kit.
Nearby in the range: MV-DP2120 — Prefer it when an 80 mm Z range with rates up to 23.9 kHz meets the application; MV-DP3300 — Prefer it for a 210 mm Z range and 183 mm reference field at rates up to 46.7 kHz.
Cables and accessories for this model
Compatibility per manufacturer data.
- Other
- 3D accessories
FAQ
How do MV-DP3120-01D and 01P differ in range and field?
The 01D execution covers 80 mm along Z at a 117 mm distance, with an X field from 57 to 91.4 mm. The 01P and 03P executions cover 86 mm at 126 mm, and their X field expands from 65 to 105 mm.
What scan rate do the MV-DP3120 executions provide?
All executions list a 3.4 to 46.7 kHz high-frame-rate range and retain 3200 points in each profile.
What vertical performance is stated for the two MV-DP3120 executions?
The 01D entry gives 1.48 µm repeatability and 3.9 to 7.56 µm Z resolution. The 01P and 03P entries give 1.68 µm repeatability and 4.38 to 8.33 µm Z resolution, paired with their deeper 86 mm range.
How do the MV-DP3120 housings and power figures compare?
MV-DP3120-01D measures 240 × 96.5 × 65 mm, weighs about 1407 g and typically uses 28 W. The 01P housing is 144.5 × 96 × 58 mm, about 950 g and typically 17.2 W. Both use 24 VDC.
What network and I/O connections support MV-DP3120 integration?
Both executions use 1000 Mbit/s Gigabit Ethernet with 100 Mbit/s Fast Ethernet compatibility. The 12-pin M12 connection carries power and I/O; 01D lists three differential inputs, while 01P lists isolated and differential inputs.
Which software choices are stated for acquiring MV-DP3120 profiles?
The listed environments are 3DMVS, VM3D and third-party software. They receive the 3200-point profile stream over Gigabit Ethernet, with the active data rate determined by the selected 01D or 01P execution.