Galvanometer laser 3D camera · MV-RS Galvanometer Laser 3D Camera
Hikrobot MV-RS-Base-M
- Lead time
- from 5 days
- Warranty
- 36 months
Medium-range tasks and neighbours
A 400 mm measurement range beginning at an 800 mm working distance gives MV-RS-Base-M a medium-range RGB-D geometry. It produces a 3200 × 1944 RGB frame and 1632 × 1264 depth map in 0.4 s to 0.9 s. The 450 nm Class 2 laser and Gigabit Ethernet interface combine with 0.10 mm accuracy at 1000 mm for measured capture over moderate-size work areas.
The view grows from 430 mm × 380 mm at 800 mm to 720 mm × 580 mm at 1200 mm. This progression fits container localization, robot approach planning and height inspection where the scene is broader than a close-range station but does not require a long standoff. IP65 protection and a 0 °C to 45 °C operating range support fixed installation in an industrial cell.
MV-RS-Base-M sits between the MV-RS-Base-S and MV-RS-Base-L geometries: MV-RS-Base-S begins at 400 mm and reaches 0.05 mm accuracy at 600 mm, while MV-RS-Base-L begins at 1200 mm and spans 1000 mm in depth. MV-RS-Ultra-M covers a 700 mm range and increases depth output to 2448 × 2048, making it the choice when a denser, deeper medium-range capture is needed.
Overview
A galvanometer 3D camera: a scanner sweeps the laser beam across the scene, two cameras capture the result, and the device builds a point cloud of the whole part in one shot, with no conveyor motion. Acquisition takes 0.4 to 0.9 seconds.
The main use is robot guidance: bin picking, palletising, depalletising. It works together with RobotPilot and VM3D.
Specifications
| Data interface | GigE |
| 3D acquisition time | 400…900 ms |
| Depth measurement range | 400 mm |
| Depth resolution (W × H) | 1632×1264 px |
| Measurement accuracy | 0.1 mm @ working distance 1000 mm |
| Reference field of view | 570×480 mm (typical) @ working distance 1000 mm |
| Laser safety class | 2 |
| Wavelength | 450 nm |
| Client software | RobotPilot, HiViewer |
| Operating systems | Windows 7 (32/64-bit), Windows 10 (32/64-bit), Windows 11 (64-bit) |
| Digital I/O lines | 3 inputs, opto-isolated, lines 0, 3, 6; 3 outputs, opto-isolated, lines 1, 4, 7 |
| Digital input count | 3 |
| Digital output count | 3 |
| Digital I/O connector | M12 12-pin |
| Power supply | 24 V |
| Power consumption | 12 W (typical) @ DC, supply voltage 24 V |
| Ingress protection | IP65 |
| Working temperature | 0…45 °C |
| Storage temperature | -30…80 °C |
| Humidity | 20…85 % @ non-condensing |
| Dimensions | 236.3×79.8×98.5 mm |
| Weight | 1300 g (approx.) |
| Certification | RoHS |
| Clearance distance | 800 mm |
| Far field of view | 720×580 mm @ working distance 1200 mm |
| Far FOV distance | 1200 mm |
| Image output delay | 800…1500 ms |
| Near field of view | 430×380 mm @ working distance 800 mm |
| Near FOV distance | 800 mm |
| Output data type | original image, mono image, RGB image, depth image, RGB_D |
| Reference FOV distance | 1000 mm (typical) |
| RGB resolution (W × H) | 3200×1944 px |
| Z repeatability | 80 µm @ working distance 1000 mm |
Documents
Selection and applications
Medium-range RGB-D acquisition over 400 mm in depth. Robot work-area capture from an 800 mm standoff. Dimensional checks at 0.10 mm accuracy at 1000 mm.
Minimum kit: Use the MV-RS-Base-M unit with a Gigabit Ethernet cable, a 12-pin M12 power and I/O cable, and a 24 V DC source sized for typical 12 W consumption.
Nearby in the range: MV-RS-Base-S — Prefer it for a 400 mm working distance and 0.05 mm accuracy at 600 mm; MV-RS-Ultra-M — Prefer it for 2448 × 2048 depth output and a 700 mm measurement range; MV-RS-Base-L — Prefer it when a 1200 mm working distance and 1000 mm range are required.
Cables and accessories for this model
Compatibility per manufacturer data.
- Power
- Power
- Other
- 3D accessories
FAQ
Which working volume is defined for the MV-RS-Base-M camera?
Its measurement range is 400 mm and its nominal working distance is 800 mm. The view measures 430 mm × 380 mm at 800 mm, 570 mm × 480 mm at 1000 mm, and 720 mm × 580 mm at 1200 mm.
What RGB and depth outputs are available from MV-RS-Base-M?
The RGB channel is 3200 × 1944 and the depth channel is 1632 × 1264 points. A complete acquisition takes 0.4 s to 0.9 s, with both outputs transferred over the 1000 Mbit/s Gigabit Ethernet connection.
How repeatable are measurements made by MV-RS-Base-M?
At 1000 mm, the stated accuracy is 0.10 mm and repeatability is 0.08 mm. Those values are tied to that distance, so the mechanical installation should preserve the intended camera-to-scene geometry during repeated inspection or localization cycles.
How are MV-RS-Base-M power and control signals connected?
The unit takes 24 V DC and typically consumes 12 W. Its 12-pin M12 interface provides power and I/O, including three opto-isolated inputs and three opto-isolated outputs, while RGB-D data travels over Gigabit Ethernet.
Can MV-RS-Base-M operate in a dust-exposed machine cell?
The housing carries an IP65 rating and operates from 0 °C to 45 °C at 20% RH to 85% RH without condensation. It measures 236.3 mm × 79.8 mm × 98.5 mm and weighs about 1.3 kg, values that matter when sizing the support.